password save
 
 
 
 
 
 
 

 
BROWSE대한건축학회 논문집(구조계)2017-04 > DETAIL
  LITERATURE >JOURNALS [347630] Download the full text :   
Title   도시열섬 완화를 위한 쿨 루프 성능평가 / 서울시 `강남구보건소'를 대상으로 / Performance Evaluation of Cool Roof for Mitigating Urban Heat Island Effects - Case Study of 'GangNam-gu Public Health Center' in Seoul, South Korea -
Authors   박소희(Park, So-Hee) ; 공경배(Kong, Kyoung-Bae) ; 민현준(Min, Hyun-Joon)
Organization   대한건축학회
Source   대한건축학회논문집 구조계, Vol.33 No.04(2017-04)
Page   Start Page(55) Total Page(8)
ISSN   1226-9107
Classification   환경 및 설비 / 도시 
Keywords   쿨 루프 ; 열섬현상 ; 반사율 ; 알베도 ; 방사율 ; 서울시//Cool Roofs ; Heat Island ; Solar Reflection ; Albedo ; Thermal Emittance ; Seoul
Abstract2   The summer heat due to global warming is getting progressively worse each year. In particular, the unprecedented heat wave in summer 2016, average and maximum temperatures compared to the normal 0.9-1.6 ℃, 0.9-2.2 ℃ higher incidence was observed in the issues of society during July and August. In the case of the city center, as the heat of the daytime is stored in the ground, it does not evaporate normally by dust, lack of greenery and waterfronts led to the heat island phenomenon. Thus, a cool-roof way to reduce the urban heat island phenomenon is getting attention. A cool roof is a method to lower the temperature of the roof surface by increasing the emissivity and solar reflectance. Reduced heat entering the interior roof surface temperature is lowered and helps to reduce summertime indoor temperature. In addition, it is also effective on urban tropical nights mitigated by reducing nighttime heat emitted by the heat storage structure. In this study the effect before and after by installing a cool roof to the actual building will be observed. The subjects measured where surface temperature, room temperature at the same time and environment at the Gangnam Community Health Center by installing a cool roof on 34% of the whole roof surfaces, located in Gangnam, Seoul. Measurement results show that the surface temperature of the roof construction is effective up to 12.9 ℃ reduced measurement period during the summer months, while indoor room temperature showed a difference of up to -1.46 ℃. In winter, the cool roof room’s average indoor temperature differences are -0.17℃ and 31% of the days were warmer compared with the uninstalled room. So the result shows that the cool roof did not significantly effects on increasing the heating load. In order to expand the cool roof enhanced reliability through various case analyses, form and scale, the form of a roof on a building should precede and be reviewed for a variety of environment-friendly techniques and applying green roof, cool roof and solar to be made in accordance with the conditions of the building.
Location   대한건축학회